Functional Recovery After Bicompartmental Arthroplasty, Navigated TKA and Traditional TKA
Michael A. Conditt, Stefan Kreuzer, Jennifer Jones, Sam Dalal
- 发表年份
- 2013
- 引用次数
- 3
摘要
Introduction Traditional Total Knee Arthpolasty (TKA) replaces all 3 compartments of the knee for patients diagnosed with OA. There might be functional benefit to replacing only damaged compartments, and retaining the normal ligamentous structures. There is a long history of performing multi-compartment arthroplasty with discrete components. Laskin reported in 1976 that good pain relief and acceptable clinical results were achieved at two years in patients with bi-unicondylar knee replacement [Laskin 1976]. Other authors also have reported on bi-unicompartmental knee arthroplasty achieving successful clinical outcomes [Stockley 1990; Confalonieri 2005]. Banks et al. reported that kinematics of bi-unicompartmental arthroplasties during gait demonstrated some of the basic features of normal knee kinematics [Banks 2005]. These reports suggest that a modular approach to resurfacing the knee can be successful and achieve satisfactory clinical and functional results. Objective The primary objective of this study is to compare the functional outcomes of three patient groups treated for osteoarthritis. Methods Subjects received either a modular, multicompartment knee arthroplasty (MKA) implanted with robotic-arm assistance(MAKO Surgical Corp., Fort Lauderdale, FL), a computer assisted TKA (TKA CAS) or a TKA implanted using traditional manual instrumentation (TKA T). Patients that were eligible to receive a TKA were randomly selected to receive computer assisted or traditional surgical technique and blinded to the type of TKA surgical technique utilized. We report post-operative functional outcomes including Range of Motion (ROM), Timed-up and go(TUG), and Quad strength at time intervals of 2 weeks, 6 weeks, 3 months and 6 months. The TUG test is a validated measure of patient mobility where a patient is asked to stand up from a chair, walk three meters turn around and sit back down [Boonstra, 2008]. The Quad strength assessment is measured with a hand held dynamometer (Lafayette Instruments, Lafayette, IN) while patient was seated with leg at 90 degrees flexion. The patient is asked to extend their knee while a physical therapist provides resistive forces to maintain static knee flexion. All tests were administered by one physical therapist. Results Patients that underwent MKA saw significant increase in ROM post-operatively when compared to TKA CAS patients (P Discussion Initial findings do indicate a short term improvement in functional outcomes for MKA patients when compared to TKA patients. Additional data clinical and functional data is being collected and enrollment is continuing for this study.
关键词
相关论文
Robots and Jobs: Evidence from US Labor Markets
Daron Acemoğlu, Pascual Restrepo
2019
Reach and grasp by people with tetraplegia using a neurally controlled robotic arm
Leigh R. Hochberg, Daniel Bacher, Beata Jarosiewicz 等 11 位作者
2012
Campbell-Walsh urology
Alan J. Wein editor-in-chief
2012
Stroke rehabilitation
Peter Langhorne, Julie Bernhardt, Gert Kwakkel
2011