Application of robotic technology in biomechanics to study joint laxity
B. Mangan, Mark Hurtig, James P. Dickey
- 发表年份
- 2010
- 引用次数
- 5
摘要
Primary objective: To evaluate whether in vitro joint testing using a robot with six degrees of freedom is useful for evaluating changes in joint laxity as a result of chronic osteoarthritis (OA).Research design: Repeated measures.Methods: Broyden's method of solving nonlinear systems of equations drove a hybrid method of load and position robotic control. Sheep stifles (knee joints) were loaded between 3 Nm of internal load through to 3 Nm of external load in 1 Nm increments. Kinematic and morphologic data from five healthy ovine stifles were compared to the chronic OA effects in four surgically destabilized stifles.Results: Stifles with chronic OA showed increases in stiffness while range of motion decreased. Gross morphologic changes included osteophytes and cartilage fibrillation.Discussion: Robotic testing proved useful for evaluating changes in joint mechanics as a result of chronic OA. We observed morphological changes and associated increases in joint stiffness and decreased laxity.