Comparison of Outcomes Following TiRobot-Assisted Sacroiliac Screw Fixation with Bone Grafting and Traditional Screw Fixation without Bone Grafting for Unstable Osteoporotic Sacral Fracture: A Single-Center Retrospective Study of 33 Patients
Zhaojie Liu, GU Ya, Xin Jin, Wei Tian, Haotian Qi, Yuxi Sun, Gang Li, Hongchuan Wang, Xiang Xiao, Pengfei Li, Yong‐cheng Hu, Jian Jia
- 发表年份
- 2021
- 引用次数
- 9
摘要
BACKGROUND This retrospective study from a single center aimed to compare patient outcomes following TiRobot-assisted sacroiliac screw fixation and bone grafting with traditional screw fixation without bone grafting in 33 patients with unstable osteoporotic sacral fracture (UOSF). MATERIAL AND METHODS Patients with UOSF were included and divided into 2 groups: a TiRobot-assisted surgical group with 18 patients (robot-aided sacroiliac screw fixation and bone grafting) and a standard surgical group with 15 patients (free-hand screw fixation without bone grafting). T values of bone mineral density (BMD) £-2.5 standard deviation (SD) were diagnosed as osteoporosis. Screw positioning and fracture healing time were evaluated. Functional outcomes were investigated at the final follow-up. RESULTS There were no statistically significant differences in screw positioning; however, there were satisfactory positioning rates in 94.4% (17/18) of patients in the TiRobot-assisted surgical group and 73.3% (11/15) in the standard surgical group. The advantages with TiRobot on surgical time of screw placement, fluoroscopy frequency, and total drilling times were noted (P=0.000). The nonunion rates were 5.6% (1/18) in the TiRobot-assisted surgical group and 33.3% (5/15) in the standard group (P=0.039). Healing time in the union cases had a significant difference (P=0.031). Functional outcome scores in the TiRobot-assisted surgical group were superior to that in the standard group (P=0.014). CONCLUSIONS The findings showed that TiRobot-assisted sacroiliac screw fixation and bone grafting was a safe and effective surgical treatment option that had a reduced radiation dose and improved fracture healing, when compared with standard screw fixation without bone grafting.
关键词
相关论文
Robots and Jobs: Evidence from US Labor Markets
Daron Acemoğlu, Pascual Restrepo
2019
Reach and grasp by people with tetraplegia using a neurally controlled robotic arm
Leigh R. Hochberg, Daniel Bacher, Beata Jarosiewicz 等 11 位作者
2012
Campbell-Walsh urology
Alan J. Wein editor-in-chief
2012
Stroke rehabilitation
Peter Langhorne, Julie Bernhardt, Gert Kwakkel
2011