首页 /研究 /Robotic single-access splenectomy using the Da Vinci Single-Site® platform: a case report
SURGICAL

Robotic single-access splenectomy using the Da Vinci Single-Site® platform: a case report

Francesco Corcione, Umberto Bracale, Felice Pirozzi, Diego Cuccurullo, Pier Luigi Angelini

发表年份
2013
引用次数
12

摘要

BACKGROUND: Single-access laparoscopic splenectomy can offer patients some advantages. It has many difficulties, such as instrument clashing, lack of triangulation, odd angles and lack of space. The Da Vinci Single-Site® robotic surgery platform could decrease these difficulties. We present a case of single-access robotic splenectomy using this device. METHODS: A 37 year-old female with idiopathic thrombocytopenic purpura was operated on with a single-site approach, using the Da Vinci Single-Site robotic surgery device. RESULTS: The procedure was successfully completed in 140 min. No intraoperative and postoperative complications occurred. The patient was discharged from hospital on day 3. CONCLUSIONS: Single-access robotic splenectomy seems to be feasible and safe using the new robotic single-access platform, which seems to overcome certain limits of previous robotic or conventional single-access laparoscopy. We think that additional studies should also be performed to explore the real cost-effectiveness of the platform.

关键词

MedicineSplenectomyRobotic surgerySurgeryLaparoscopyComputer scienceRoboticsGeneral surgeryArtificial intelligenceRobot

相关论文