Dosimetric quality and delivery efficiency of robotic radiosurgery for brain metastases: Comparison with C‐arm linear accelerator based plans
Shuming Zhang, Ruijie Yang, Xin Wang
- 发表年份
- 2019
- 引用次数
- 15
- 访问权限
- 开放获取
摘要
Abstract The incidence of brain metastases is increasing and various treatment modalities exist for brain metastases. The aim of this study was to investigate the dosimetric quality and delivery efficiency of robotic radiosurgery (CyberKnife) for multiple brain metastases compared with C‐arm linear accelerator (linac) based plans. C‐arm linac based plans included intensity‐modulated radiation therapy (IMRT), volumetric modulated arc therapy (VMAT) and non‐coplanar VMAT with 1, 3 and 5 non‐coplanar arcs, respectively (NC1, NC3 and NC5). For 20 patients, six plans with a prescription dose of 30 Gy in three fractions were generated. The gradient index (GI), conformity index (CI), maximum dose (D max ) of organs at risk (OARs), normal brain tissue volume (V 3 Gy –V 24 Gy ), monitor units (MUs) and beam on time (BT) were evaluated. The GI of CyberKnife plans (3.60 ± 0.70) was lower than IMRT (6.21 ± 2.26, P < 0.05), VMAT (6.04 ± 1.93, P < 0.05), NC1 (5.16 ± 1.71, P < 0.05), NC3 (5.02 ± 1.59, P < 0.05) and NC5 (5.03 ± 1.72, P < 0.05). The CI of the VMAT plans (both coplanar and non‐coplanar) was larger than IMRT and CK plans. The D max for most OARs of the CyberKnife plan was lower than the C‐arm linac based plans, although some differences were not statistically significant. The normal brain tissue volume of CyberKnife plan was lower than the C‐arm linac based plans, and the normal brain tissue volume of non‐coplanar VMAT plans was lower than IMRT and VMAT plans at high‐moderate dose level. However, the MUs and BT of CyberKnife plans was more than C‐arm linac based plans. CyberKnife plan was better than C‐arm linac based plans in protecting normal brain tissue and OARs for patients with multiple brain metastases. C‐arm linac based plan with non‐coplanar arc provided better protection of normal brain tissue than coplanar plan. However, the BT of CyberKnife plan was longer than C‐arm linac based plans.
关键词
相关论文
Robots and Jobs: Evidence from US Labor Markets
Daron Acemoğlu, Pascual Restrepo
2019
Reach and grasp by people with tetraplegia using a neurally controlled robotic arm
Leigh R. Hochberg, Daniel Bacher, Beata Jarosiewicz 等 11 位作者
2012
Campbell-Walsh urology
Alan J. Wein editor-in-chief
2012
Stroke rehabilitation
Peter Langhorne, Julie Bernhardt, Gert Kwakkel
2011