首页 /研究 /Evaluating control modes for constrained robotic surgery
SURGICAL

Evaluating control modes for constrained robotic surgery

Fengchang Lai, Robert D. Howe

发表年份
2002
引用次数
23

摘要

Minimally invasive surgery (MIS) constrains instrument motions to 4 DOF by precluding lateral motion at the incision. Robotic MIS systems can interpose arbitrary mappings between the surgeon's motions at the master controller and the motions of instrument tips within the patient's body. Our goal was to find the interface that was easiest to learn. We investigated the effects of different coordinate frame mappings (screen-mapped versus instrument-mapped) and master dexterities (6 DOF versus 4 DOF) by means of performance measures on simple surgical tasks. All four mode-dexterity combinations had approximately the same time-to-completion. The combination of instrument-based mapping and 4 DOF master had lower error rate and lower subjective workload. This mode most clearly reproduces the task constraints within the patient's body.

关键词

Computer scienceControl (management)Artificial intelligence

相关论文