MStern Blotting–High Throughput Polyvinylidene Fluoride (PVDF) Membrane-Based Proteomic Sample Preparation for 96-Well Plates
Sebastian T. Berger, Saima Ahmed, Jan Muntel, Nerea Cuevas Polo, Richard G. Bachur, Alex Kentsis, Judith A. Steen, Hanno Steen
- 发表年份
- 2015
- 引用次数
- 87
- 访问权限
- 开放获取
摘要
We describe a 96-well plate compatible membrane-based proteomic sample processing method, which enables the complete processing of 96 samples (or multiples thereof) within a single workday. This method uses a large-pore hydrophobic PVDF membrane that efficiently adsorbs proteins, resulting in fast liquid transfer through the membrane and significantly reduced sample processing times. Low liquid transfer speeds have prevented the useful 96-well plate implementation of FASP as a widely used membrane-based proteomic sample processing method. We validated our approach on whole-cell lysate and urine and cerebrospinal fluid as clinically relevant body fluids. Without compromising peptide and protein identification, our method uses a vacuum manifold and circumvents the need for digest desalting, making our processing method compatible with standard liquid handling robots. In summary, our new method maintains the strengths of FASP and simultaneously overcomes one of the major limitations of FASP without compromising protein identification and quantification. We describe a 96-well plate compatible membrane-based proteomic sample processing method, which enables the complete processing of 96 samples (or multiples thereof) within a single workday. This method uses a large-pore hydrophobic PVDF membrane that efficiently adsorbs proteins, resulting in fast liquid transfer through the membrane and significantly reduced sample processing times. Low liquid transfer speeds have prevented the useful 96-well plate implementation of FASP as a widely used membrane-based proteomic sample processing method. We validated our approach on whole-cell lysate and urine and cerebrospinal fluid as clinically relevant body fluids. Without compromising peptide and protein identification, our method uses a vacuum manifold and circumvents the need for digest desalting, making our processing method compatible with standard liquid handling robots. In summary, our new method maintains the strengths of FASP and simultaneously overcomes one of the major limitations of FASP without compromising protein identification and quantification. Mass spectrometry (MS)-based proteomics is moving increasingly into the translational and clinical research arena, where robust and efficient sample processing is of particular importance. The conventional sample processing methods in proteomics, namely SDS-PAGE, or in-solution-based sample processing, are slow and laborious and thus do not easily provide the reproducibility and throughput to meet current demands. A paradigm shift was the introduction of a filter-aided sample processing method (FASP), which is initially described by Manza et al. (1.Manza L.L. Stamer S.L. Ham A.J. Codreanu S.G. Liebler D.C. Sample preparation and digestion for proteomic analyses using spin filters.Proteomics. 2005; 5: 1742-1745Crossref PubMed Scopus (321) Google Scholar) and then fully realized in practice by Wisniewski et al. (2.Wiśniewski J.R. Zougman A. Nagaraj N. Mann M. Universal sample preparation method for proteome analysis.Nature Meth. 2009; 6: 359-362Crossref PubMed Scopus (5097) Google Scholar). These filter-aided methods make use of ultrafiltration membranes with molecular weight cut offs (MWCO) in the 10 to 30 kDa range to efficiently remove small molecules and salts and to capture denatured proteins on a cellulose filter even if the molecular weight of the protein is much smaller than the nominal MWCO of the ultrafiltration membrane. Thus, the denaturation step is crucial to ensure that proteins much smaller than the nominal MWCO are efficiently retained by, e.g. a 10 kDa MWCO filter. In translational and clinical proteomics, which normally include large cohorts, the multititer-well plate is the preferred format for sample processing and storage. Although the application of FASP in the 96-well plate format has been described (3.Switzar L. van Angeren J. Pinkse M. Kool J. Niessen W.M. A high-throughput sample preparation method for cellula
关键词
相关论文
Statistical Learning Theory
Yuhai Wu, Vladimir Vapnik
1999
Artificial intelligence: a modern approach
1995
Fractional Differential Equations
Igor Podlubný
2025
Applied Nonlinear Control
Jean-Jacques Slotine, Weiping Li
1991